BRAND | Stahl |
Product | 6148/3111-111 (268713) |
Description | Ex KFZ hand lamps |
Internal code | IMP4939109 |
Custom code | 85131000 |
Technical specification | Rated operating voltage AC: 110.00 - 240.00 V Rated operating voltage DC: 12.00 - 30.00 V Case material: Polyamide, impact-resistant Number of lamps: 2 Light source: LED Light intensity: 40,000 cd Light color: 6500 K Light distribution: in accordance with DIN 14642 Diffuser design: Clear Orange Protection class: II (insulated) Battery version: lead-fleece battery maintenance-free, 6 V, 4.5 Ah Type of connection cable: 12... 30 V DC charging cable Plug: free ends, 2-pin Cable length: 1.8 m Dimensions (L x W x H): 279 x 92 x 143 mm Protection class (IP): IP66 Range of use (zones): 1, 2, 21, 22 Gas explosion protection: II 2 G Ex ib IIC T4 Gb Dust explosion protection: II 2 D Ex tb IIIC 75 °C Db |
Discover the superior quality and performance of the Stahl 6148/3111-111 (268713) with Impexron GMBH in New Zealand . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The 6148/3111-111 (268713) is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of 6148/3111-111 (268713) :
At Impexron GMBH , we offer the 6148/3111-111 (268713) at competitive prices and with the fastest delivery times across New Zealand . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the 6148/3111-111 (268713) ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Stahl products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Two-pin fluorescent lamp
(Sodium high-pressure lamp 400W, tubular form)
6000/521-8011-3130 Lighting with 2-pin 1x18/20W
Lighting with 2-pin 1x18/20W Light Fittings for Fluorescent Lamps Series EXLUX 6000, explosion protected Lamps Number of lamps: 1 Lamp wattage: 18 W Monitoring module: without Material Enclosure: Polyester resin, glass fibre-reinforced / Colour white, similar to RAL 9010 Lamp cover: Polycarbonatean aromatic-resistant paint can be used For use in: Zones 1 & 2, 21 & 22 CCT No.: 94054035 DE Net weigth: 4,100 KG
6000/522-9011-0130 Light fitting with 2pin 18/20W
(Breather M25)
(Through wiring DV5 20W accessorie)
(Through wiring DV5 65W accessorie)
(Insert plate 2xM25x1,5 accessories)
Lamp socket
Repair Kit 36W electronic ballast + Accessories
6108/1081-8017-74-00 Compact emergency light fitting 1x8W
Auxiliary lens, clear
Lead-gel Battery with fuse;4 V;3.5 Ah
Main lamp(halogen lamp), 4.0 V;2 W; packing unit 2 pc’s
Economy lamp 3.7 V; 1.1 W; packing unit 10 pc’s
(Hand lamp explosion-protected Type : 6147/2-2 Enclosure material : Light metal Protective glass material : Temperature-resistant pressed glass Lamp wattage : 25 W, 40 W, 60 W Rated operational voltage AC : 230 V Rated operational voltage DC : 230 V, 24 V, 42 V Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de IIC T.. Dust explosion protection : II 2 D Ex tb IIIC 145 °C Min. ambient temperature : -20 °C Max. ambient temperature : +40 °C Type of protection (IP) : IP65 Connection : 1 x M20 mit Zugentlastung)
6388/1-2-2 Bulkhead light fitting Bulkhead Light Fitting Series 6388, explosion protected Lamps: up to 150 W Colour of glass: clear For use in: Zones 1 & 2
6508/1081-8017-74-00 Compact emergency light fitting 1x8W
Fluorescent luminaire explosion proof housing material: Polyester resin When Material: Polycarbonate Number of lamps: 2Lampenleistung: 18 WBemessungsbetriebsspannung AC: 240 VBemessungsbetriebsspannung DC: 254 VEinsatzbereich (zones): 2, 21, 22Gasexplosionsschutz: II 3 G Ex nA IIC T4Staubexplosionsschutz: II 2 D Ex tb IIIC 80 ° CUmgebungstemperatur min , : Max -25 ° CUmgebungstemperatur. : +55 ° CSchutzart (IP): IP66Durchverdrahtung: without closing plug: 2 x M25 x 1,5Für further information see: www.stahl.de Webcode 6600ALeuchte luminaire series ECOLUX 6600, explosion-protected lamp fitting lamp number: 2Lampenleistung: 18 WElektronisches gear: 1 channel EVGÜberwachungsbaustein: without through-wiring: without / case material: polyester resin, fiberglass-reinforced, color white, similar to RAL 9010Wanne: polycarbonate protective paint möglichEinsetzbar in: zones 2, 21 & 22
(Fluorescent luminaire, Type: 6600/52.-....-...., Specifications: Gas explosion: II 3 G Ex nA II T4 dust - Explosion protection: II D 2 T 80 ° C Test Certificate: DMT 01 E 085 / E ATEX 086X Suitable for: Fluorescent lamp 2Stift, 1 x 18W Reflector design symmetric wide distribution Material: Polyester resin surface: Without color IP 66 Ambient temperature: -20 ° C ... 55 ° C Rated voltage: QTP Osram: 220 V ... 240 V -10% + 10%; 50/60 Hz Cable entry: 2 x cable entry M25x1.5 1 x sealing plug M25x1.5 without bulbs Through wiring with 5 wires)
(Light fitting for fluorescent lamps explosion-protected Type : 6600/542-8010-2230 Enclosure material : Polyester resin Lamp cover material : Polycarbonate Number of lamps : 2 Lamp wattage : 36 W Rated operational voltage AC : 240 V Rated operational voltage DC : 254 V Application range (Zone) : 2 , 21, 22 Gas explosion protection : II 3 G Ex nA IIC T4 Dust explosion protection : II 2 D Ex tb IIIC 80 °C Min. ambient temperature : -25 °C Max. ambient temperature : +55 °C Type of protection (IP) : IP66 Through wiring : without Connection : 1 x M25 x 1,5 Plug : 2 x M25 x 1,5 CCT No.: 94054035 DE Net weigth: 5,000 KG)
(MontageschieneZubehoer)
(WandbefestigungswinkelZubehoer)
8003 / 131-008-2-r-MS1 key switch SS cage clamp command button / switch for panel mounting Series 8003, explosion-proof: key switch, 8003/1 008-2 Locking ..-: Standard connection: spring terminals with terminal chamber contacts: NO / NO contact material : silver-nickel switching position: 2 positions, latching use in: zones 1 & 2, 21 & 22
LED Indicating Lamp for panel mounting explosion-protected Type Rated operational voltage AC : 254 V Enclosure material : Polyamide Luminous colour : blue green red white yellow Version : with connection chamber Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex de mb IIC T6 Min. ambient temperature : -30 °C Max. ambient temperature : +55 °C Type of protection (IP) : IP65 Electric service life : 10.000 lighting hours CCT No.: 85318095 DE Net weigth: 0,130 KG
8030 / 51-033 installation switch 2-pole switch, Rated operating voltage: 250 V DC / 690 V AC
Installation switch, 2-pol, ON-OFF Installationsschalter Reihe 8030/51, explosion protected Version: OFF switch Number of poles: 2-pole Material Enclosure: Polyester Cover: Polyamide For use in: Zones 1 & 2, 21 & 22 CCT No.: 85365080 DE Net weigth: 0,600 KG