NXc80  - Liebert New Zealand  Sales

BRAND Liebert
Product NXc80
Internal code IMP3404907
Weight 1
Technical specification MANUFACTURER VERTIV Origin Italy Model LIEBERT NXc80 Nominal output 80kVA / 72kW Power factor 0,9 Parallel configuration 4 Phases Input / Output 3/3 Communication RS-232, SNMP-option INSERT DISTRIBUTOR Input voltage VAC 380/400/415 Input voltage range VAC 305 - 477 Rated frequency Hz 50/60 Frequency range Hz 40 - 70 Input power factor kW / kVA 0,99 Thrust distortion THDi at full linear load % <3 PERMANENT CHAIN Voltage VDC Nominal 384, (300 - 635) Number of battery cells in 1 string Max. 264, Minimum 180 Battery type VRLA OUTPUT INVERTER Voltage (three phase) VAC 380/400/415 Voltage tolerance at linear load% ± 1 Frequency Hz 50/60 Overloading 60 min. Continuous work 10 min. 125 1 min. 150 <200 ms%> 150 THDv voltage distortion at 100% linear load % 2 BIAPAS Voltage VAC 380/400/415 Voltage tolerance% + 20 / -40 Frequency Hz 50/60 Frequency Tolerance with Sync with inverter HZ ± 20 (± 10 selectable) EFFICIENCY AND HEAT LOSS Efficiency in normal mode (double conversion)% 95.7 Efficiency in ESO mode% 99.2 Heat losses at 100% (54kW) load kW 3.5 WORKING ENVIRONMENT Noise level at 1m (front) dBA ≤59 Altitude m ≤1500 Relative humidity% 0-95, no condensation Recommended working temperature of bat. o 15-15 ° C UPS storage and transport temperature -40 to +70 Recommended storage temperature batteries oC - 20 to 30 (20 ° C optimal) MECHANICAL CHARACTERISTICS Dimensions (WxHxD) VDC 600x1000x1600 Weight (without batteries) Kg 385 Degree of protection IP20 STANDARDS General safety requirements EN62040-1 / IEC62040-1 Electromagnetic Compatibility Requirements (EMC) EN62040-2 / IEC62040-2 (class C2) UPS classification according to VFI-SS-111

Please Contact Us to Order to offer competitive prices and delivery time for Liebert - NXc80 number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in New Zealand Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Liebert

Challenger 3000

Closed Control 10.5kW R410.

GXT3-10000T230

UPS distribution system

GXT3-240TBATTCE

Battery pack of Emerson Network Power

GXT3-3000RT230

Power 3000VA / 2700WattBridging time 5 min. At 100% loadUSB / IntellislotDauerwandler- (True Online) TechnologyDimensions: 88x602x430 (mm)Weight: 28kg

GXT3-72VBATT

Battery module 72V GXT3 Dimensions (WxDxH): 85x602x430 (2U) Weight: 42kg Up times at 100% load: without Batt.erw. 4 min. with a Batt.erw. 18 min. with two Batt.erw. 44 min. Three Batt.erw. 62 min. with four Batt.erw. 84 Min.

HPM – L8FUA

Efficient Direct Expansion Cooling for Data Centers

NXC 10KVA UPS 3/3PHASE

Uninterruptible Power Supply

PH045DC

HPAC Emerson Liebert‐Hiross, model PCW – PH045DC – precision cooling unit, chilled water version with Downflow – UP (Fan module is over the raised floor) air delivery. • Net Total Cooling Capacity TCC= 54,8 kW; • Net Sensible Cooling Capacity SCC= 44,9 kW;

PSI3 2200RT3-230

On-Line UPS

PS2200RT3-230

Rack/tower UPS

AS6C1NCJH1NX462

APS Battery Module

GXT4-6000RT230

USB / Intellislot

APM0600CS10000 APM150K unavailable

Kesintisiz Güç Kaynağı

Contact us for request