HC2 probe extension cable  - Rotronic New Zealand  Sales

BRAND Rotronic
Product HC2 probe extension cable
Internal code IMP4695658
Technical specification Cable for HC2A-S and HF532-WBA3X1XX 2M

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Rotronic - HC2 probe extension cable number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in New Zealand Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Rotronic

HF532-WBD6X1XX

Transmitter for humidity and temperature wall-mounted version, 3/4-wire, horizontal mounting, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 1 M16x1.5 gland, output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

HF532-WBD6X5XX

transducer

HF632 – DB 1 XX 21XX - obsolete, replacement HF732- PB1XX21XX

transmitter, Power : 15 – 40 VDC / 12 - 28 VAC, OP.Range : -400… / + 60 oC, Out H : 0….100 % RH 4-20 mA, Out T : 0….+50oC 4-20 mA

HF732- PB1XX21XX

Transmitters for humidity and temperature Channel model with 550 mm probe length, PPS trunk 15 mm, 3/4-wire version, IP65 aluminum die-cast housing, Power supply: 15 ... 40 VDC / 12 VAC ... 28, Connection: 1 M16x1.5 stainless steel nuts, Output signals: OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 50 ° C.

HF732-QBD6XSFXX

Messumformer

HF732-QBD6XSFXX

Transmitter for humidity and temperature channel design with 250 mm probe length, PPS trunk 25/15 mm, 3/4-wire version, IP65 die-cast aluminum casing, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 7-pole plug tuchel, (+ supply signals), output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

HF732-QBD6XSFXX

Transmitter for humidity and temperature channel design with 250 mm probe length, PPS trunk 25/15 mm, 3/4-wire version, IP65 die-cast aluminum casing, power supply 15 ... 40 VDC / 12 ... 28 VAC, connection: 7-pole plug tuchel, (+ supply signals), output signals OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = 0 ... 150 ° C.

HIYGROMER

Moisture meter

HL-20D

(Data logger for relative humidity and Temperature with display with integrated sensors, Display with backlight, Alarm via LED display, Battery status display, Function key: start / stop logging, Real-time function (RTC) Loop or start / stop storage mode, Measuring range: 0 ... 100% RH / 0 ... 50 ° C, Accuracy (23 ° C): ± 0.8% RH / ± 0.2 ° C, Repeatability: ± 0.3% RH / ± 0.05 ° C, Long term stability: <1% RH / 0.1 ° C / year, Calculations: dew or frost point, Log-interval: 5 seconds to 1 hour, Interface: UART to USB (via AC3006) Housing material: ABS, Dimensions: 130 x 72 x 32 mm, Weight: about 270 g).

HP 21

Hand-held instrument with an integrated probe for humidity and temperature.

HP22-A

Handmessgeräte HygroPalm 22 für austauschbare HygroClip2-Fühler

HP-22-SET

Sensor module for humidity and temperature HC2-S; 1 calibration ER-15; 1 Humidity standard EA80-SCS; 1 extension cable E2-02A; 1 Service case AC1127

HP23-A

Hand-held instrument for 2 Sensor Module HC-2 or 2 analog sensor inputs (for 0.1 VDC or 0:20 mA), 9 V battery, calculating Absolufeuchtewerten, real-time clock with battery backup, Probe adjustment directly Taupunktreferenz, remote control ungsfunktion for transmitters, application range unit: 0 ... 100% rh / -10 ... 60 ° C measuring ranges depending sensor, mini USB interface Stores up to 16,000 readings: Each data sets contains humidity, temperature, date, time, batch number and user ID number ...

HP23-AW-A

(Aw or% rh and ° C) hand-held instrument for quick AW measurement for humidity and temperature, calculation of all psychrometric humidity values, including internal memory for 20,000 records with real-time clock, data-capture function, mini-USB port (UART), Application : 0 ... 1 aw (0 ... 100% rh) / -10 ... 60 ° C, precision: sensor-dependent, automatic determination of the equilibrium state, including AW-qUICK-function for fast measurement of water activity.

HP23-AW-A SET

Portable Water Activity System

HT800

humidity sensor

HTS11X

Industrial transmitter with instructions HygroFlex 1 12-35VDC / 24VAC, 2 analog outputs, 1 digital sensor input.

HTS12 X

out 1:HO... 100%RH 4-20ma out 2:TO...100C 4-20ma

HTS31X

3 analog outputs, 1 digital output, RS232 interface, network compatible (RS485), optional 2nd sensor input connector 5-pole, 4 ... 20 mA = 0 ... 100% RH, 0 ... 100 ° C and calculated value, 1 x M16 cable glands Power supply: 12 ... 35 VDC / 12 ... 24 VAC

HYGROCLIP HC2-HP28

Insertion Probe - Barrel: 280mm x 10mm dia., 2m cable - Operating Range: -40…185ºF (-40…85ºC)

HYGROCLIP-IC -3- 15/25

Interchangeable digital PPS cable sensor

HYGROCLIP-IC-4

Digital PPS cable probe special version: sensor dimensions 15 x 400 mm, including filter support, range -50 ... + 200 ° C.

HYGROFLEX3 - HF3

ensor transmitter Temperature and Humidity

MP402H-080300

HygroMet Meteorology probe for S3 HC2-supply voltage: 15 ... 24 VDC, Vmin = 10 V + (0,02xBürde), Electronics operating range: -40 ... 85 ° C, Protection: IP65, OUT1: 4 ... 20 mA = 0 ... 100% RH, OUT2: 4 ... 20 mA = -40 ... 60 ° C, connection: 3 m cable with open ends.

SCS-FIRST-1T-5H

SCS calibration with SCS certificate @ 23 ° C; 20, 35, 50, 80, 90% RH